Mersen AJT25 25 Amp, 600 Volt, Class J Time Delay Fuse
Mersen AJT25 25 Amp, 600 Volt, Class J Time Delay Fuse
Mersen | ID: 1705
Manufacturer Part Number: AJT25

Technical Documents
Specifications
Alternate Catalog Number | AJT25 |
American Recovery and Reinvestment Act (ARRA) Compliant | X |
Amperage Rating | 25 A |
Application | Motor circuits Mains Feeders Branch circuits Lighting, heating & general loads Transformers Control panels Circuit breaker back-up Bus duct Load centers |
Brand Name | Mersen |
Buy American Act (BAA) Compliant | X |
Catalog Description (MFR) | Fuse AJT - Class J - Time-delay 600VAC 400VDC 25A Ferrule SmartSpot® Amp-Trap 2000® |
Certifications | CSA,UL |
Class | Class J |
Commodity Code | 6113 |
Concatenated Invoice Description | Fuse AJT - Class J - Time-delay 600VAC 4 |
Connection | Ferrule |
Description | MFZ AJT25 600V CLASS J TD FUSE |
Fuse Type | Time Delay |
Interrupt Rating | 200 |
Invoice Description (MFR) | Fuse AJT - Class J - Time-delay 600VAC 400VDC 25A Ferrule SmartSpot |
Marketing Message (MFR) | Amp-Trap 2000® AJT fuses provide non-indication as well as a SmartSpot visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No Damage protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT’s time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability. |
Mounting | Clip |
Product Name | Low Voltage UL Power Fuse |
Safety Data Sheet (SDS) Flag | N |
Shipping Restrictions (MFR) | No Shipping Restrictions |
Short Description | J TD FUSE 600V 25A AJT |
Size | 2.25 x 0.81,57.15 x 20.65 |
Special Features | Non-indicating or solid state SmartSpot visual blown fuse indicator Time-delay for motor starting and transformer inrush 300kA interrupting rating - self-certified, UL witnessed tests Extremely current-limiting for low peak let-thru current Most current-limiting UL class fuse Recommended for Arc Flash energy reduction Small footprint requires less mounting space and allows smaller, more economical fuse blocks Easy 2-to-1 selectivity for prevention of nuisance shutdowns Unique Class J dimensions prevent replacement errors High-visibility orange label gives instant brand recognition Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings High-grade silica filler ensures fast arc quenching Optional EI indicator/switch mount for AJT70 to 600 open fuse indication |
Standard | AJT (1-600): UL listed to standard 248-8 File E2137 DC listed to UL standard 248 CSA certified to standard C22.2 No. 248.8 IEC 60269-2-1 AJT (70-600) EI: UL listed DC tested to UL standard 248 |
Stripped Catalog Number | AJT25 |
Sub Brand | Amp-Trap 2000® |
Substitutes | 634206 |
Type | Class J |
Type Of Indicators | SmartSpot® |
UNSPSC | 39121604 |
Voltage Rating | 600V |
Availability
- Akron Qty 0
- Bedford Qty 0
- Chardon Qty 0
- Cleveland Qty 0
- Lighting Showroom Qty 0
- Macedonia Qty 0
- Mayfield Village (current selection) Qty 4
- Medina Qty 0
- Middleburg Qty 0
- Streetsboro Qty 0
- Westlake Qty 0
- Willoughby Qty 0