Eaton BRP30BC100 BR 100 Amp, 60 Circuit, Main Breaker Load Center, 120/240 Volt, Single-Phase
Eaton BRP30BC100 BR 100 Amp, 60 Circuit, Main Breaker Load Center, 120/240 Volt, Single-Phase
Eaton | ID: 441900
Manufacturer Part Number: BRP30BC100

Technical Documents
Specifications
American Recovery and Reinvestment Act (ARRA) Compliant | C |
Amperage Rating | 100 A |
Application | Elec Assemblies, Panels & EOEM - Electrical Assemblies, Panels and EOEMs |
Brand Name | Eaton |
Buy American Act (BAA) Compliant | C |
Catalog Description (MFR) | Eaton BR main breaker loadcenter,100A,X5,Copper,Cover included,NEMA 1,Metallic,10kAIC,BR2100,60 circuits,Single pole,30 spaces,Two hots, a neutral, and a ground,Single-phase,Combination,Type BR 1-inch breakers,120/240V |
Certifications | UL 50, UL 67 |
Concatenated Invoice Description | BR PON LC,100A, MCB, 30 SPACE, CU BUS |
Cover Type | Cover included |
Description | EATON BRP30BC100 TYPE BR 1-INCH PONLOADCENTER |
Ean | 4015081923151 |
Height | 3.88 in |
Interrupt Rating | 10 |
Invoice Description (MFR) | BR PON LC,100A, MCB, 30 SPACE, CU BUS |
Marketing Message (MFR) | Specially designed for easy installation, Eaton's BR 1-inch load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. |
Mounting | Combination Mount |
Mounting Type | Combination |
Number Of Spaces | 30 |
Phase | 1 Phase |
Product Feature | BR load centers feature Robertson slotted square combo screwheads, which means only one screwdriver is need for installation.,Extra 1.5-inch knock-out for bundling allows maximum wiring gutter space for ease of wiring in compliance with NEC requirements.,One-piece roll-formed metal backpan with circuit breaker alignment notches ensures accurately aligned breaker and bus tabs.,Plug-on neutral design provides time and labor-savings by eliminating the pigtail.,Standard 14-3/8 inches (365.1 mm) wide enclosures fit snugly between wall studs.,Tangential main knock-out eliminates the need for conduit offsets, which permits faster, easier installation.,Twin neutral design located in wireway, away from circuit breakers, means easier wiring and balancing of the load. |
Product Name | Eaton BR main breaker loadcenter |
Product Type | Main breaker loadcenter |
Safety Data Sheet (SDS) Flag | N |
Size | X5 |
Standard | UL 50,UL 67 |
Stripped Catalog Number | BRP30BC100 |
Substitutes | 525396 |
Trade Size | 1IN |
Type | Main breaker loadcenter |
UNSPSC | 39121101 |
Voltage Rating | 120/240V |
Wattage | Single-pole |
Width | 14.31 in |